In This Section |
Farm
Structures That Require an Engineered Design
|
| Author: | Richard Brunke - Nutrient Management Engineer/OMAFRA |
|---|---|
| Creation Date: | 28 August 2007 |
| Last Reviewed: | 01 January 2007 |
All building construction in Ontario must follow the Ontario Building Code (OBC), which describes the requirements that must be met for all new or expanding buildings in the province. The code specifically defines when a building permit is required and when the building is required to be designed by an Engineer and/or Architect. An engineered drawing is a drafted plan of the facility that has been designed, reviewed and sealed with a Professional Engineer's stamp with the original signature.
The Ontario Building Code also ensures that other applicable laws, such as the Nutrient Management Act are followed. This means municipal Chief Building Officials (CBO) are required to ensure that a Nutrient Management Strategy is approved before they issue a building permit for a livestock facility or manure storage.
The OBC defines farm buildings as all or part of a building,
The construction of a farm building greater than 10 square metres
requires a building permit. Any modification within an existing farm
building that includes any changes to a structural component within
the building will also require a building permit.
The following table is a general summary of the requirements for
farm structures under the OBC. This table does not include all
the situations that will require an Engineered Design. Contact your
local municipal Chief Building Official for specifics.
| Type of structure | Size | Engineer Design & Review |
|---|---|---|
| Farm Building | Greater than 600 square metres | Required |
| Less than 600 square metres | May require engineering to address critical components. | |
| Roof Trusses | For all buildings | Required |
| Farm Building span (width) | If greater than 18.2 metres (59.54 feet) | Required |
| Farm Building height | If greater than 6 metres (19.6 feet) | Required |
| Liquid manure storages (including earthen manure storages) | All sizes | Required |
| Solid manure storages | Surface area greater than 600 square metres or have a wall greater than 1 metre of exposed height | Required |
| Wall 1 metre or less than in exposed height and a surface area of less than 600 square metres. | May require engineering to address critical components. | |
| Roof width greater than 18.2 metres (59.45 feet) | Required | |
| Building height greater than 6 metres (19.6 feet) | Required | |
| Grain bin concrete footings | Any size | Required |
| All pre-engineered farm buildings | Any size | Required |
This table does not include all the situations that will require an Engineered Design. Contact your local municipal Chief Building Official for specifics.
| Top of Page |
For more information:
This site is maintained
by the Government of Ontario
Queen's
Printer for Ontario
Last Modified: