In This Section

Milk Quality Infosheet:
Pipeline Cleaning System Guidelines

Author: Jeromy Ten Hag - Milk Quality Assurance Program Lead/OMAFRA
Creation Date: 01 September 2001
Last Reviewed: 01 September 2001


Cycle

Purpose

Temp. Range

Management Tips

1st - Pre-rinse Milkline

  • removes 90-95% of milk solids
  • removes residual milk and dirt
  • warms up milk line
  • ensures detergent isn't being diluted during next cycle
  • warm water, start temperature should be 43°C-60°C (110°F -140°F)
  • temperature at the end of cycle ideally should be above 38°C (100°F)
  • do not recirculate water -otherwise, a milk film may be redeposited on the system
  • to reduce the amount of milk in waste disposal systems, some farmers save first-rinse water and milk, and feed it to kids

2nd - Washing the Milkline with Chlorinated Alkaline Detergent

  • removes fat, protein and other organics, including a large number of bacteria
  • start temperature of wash cycle should be 71°C- 76°C (160°F-170°F) to dissolve fat in milk line
  • water to be no less than 43°C/110°F (49°C/120°F in large systems with meters) at end of the cycle so that fat can't redeposit on milk contact surfaces
  • amount of detergent depends on volume of water used and water hardness
  • follow manufacturer's recommendations as written on milkhouse wash chart
  • pH of cleaning solution used during wash cycle should be between 11-13, and its chlorine content from 100-200 ppm
  • Water qualities
    • depending on the water hardness on your farm, installation of a water softener may be necessary
  • Wash cycle

    • cycle should last 6-10 minutes
    • same water passes through milk line several times during cycle
  • minimum 20 slugs/wash
  • flow rate of 7-10 m/sec or 23-33 ft./sec.

3rd - Rinsing the Milkline with Acid Rinse

  • removes detergent residues
  • prevents build-up of mineral deposits
  • lower pH levels inhibit bacterial growth between milkings
  • helps keep rubber parts in good condition
  • water temperature must comply with manufacturer's recommendation as posted on wash chart
  • acid rinse pH should be between 2.5-3.5
  • add acid to acid rinse cycle after each milking
  • never mix an acid detergent with a chlorine-based product - mixing could produce an extremely toxic lethal gas

4th - Rinsing the Milkline with a Sanitizer

  • To disinfect system prior to milking
  • warm water 110°F - 140°F (43°C - 60°C)
  • use a solution containing 100-200 ppm chlorine
  • run cycle just prior to milking (no more than 30 minutes prior to milking) for 3-4 minutes.

Sources:
Ron Sampson, Prince Edward Island, Department of Agriculture
A&L Laboratories Inc.
Dairy Farmers' of Ontario Udder Health Management Program Staff "General Guidelines for Effective Dairy Equipment Cleaning" January 2001.

| Top of Page |

For more information:
Toll Free: 1-877-424-1300
Local: (519) 826-4047
E-mail: ag.info.omafra@ontario.ca