Vegetated Filter Strip System Design Manual
Design Tables



Table 6.1 Maximum Runoff Storage/Setting Volume Using Conservative Method (m3),
25-Year, 24-hr Storm, Holding 100%
Area of Runoff Collection Area
(m2)
Hamilton Airport
Storage/ Settling Volume*
(m3)
Discharge Rate for following Retention Periods
4 hr
(m3/s)
5 hr
(m3/s)
6 hr
(m3/s)
7 hr
(m3/s)
8 hr
(m3/s)
9 hr
(m3/s)
10 hr
(m3/s)
100 9.61 6.68E-04 5.34E-04 4.45E-04 3.82E-04 3.34E-04 2.97E-04 2.67E-04
200 19.23 1.34E-03 1.07E-03 8.90E-04 7.63E-04 6.68E-04 5.93E-04 5.34E-04
300 28.84 2.00E-03 1.60E-03 1.34E-03 1.14E-03 1.00E-03 8.90E-04 8.01E-04
400 38.46 2.67E-03 2.14E-03 1.78E-03 1.53E-03 1.34E-03 1.19E-03 1.07E-03
500 48.07 3.34E-03 2.67E-03 2.23E-03 1.91E-03 1.67E-03 1.48E-03 1.34E-03
600 57.68 4.01E-03 3.20E-03 2.67E-03 2.29E-03 2.00E-03 1.78E-03 1.60E-03
700 67.30 4.67E-03 3.74E-03 3.12E-03 2.67E-03 2.34E-03 2.08E-03 1.87E-03
800 76.91 5.34E-03 4.27E-03 3.56E-03 3.05E-03 2.67E-03 2.37E-03 2.14E-03
900 86.53 6.01E-03 4.81E-03 4.01E-03 3.43E-03 3.00E-03 2.67E-03 2.40E-03
1000 96.14 6.68E-03 5.34E-03 4.45E-03 3.82E-03 3.34E-03 2.97E-03 2.67E-03
1500 144.21 0.01 8.01E-03 6.68E-03 5.72E-03 5.01E-03 4.45E-03 4.01E-03
2000 192.28 0.01 0.01 8.90E-03 7.63E-03 6.68E-03 5.93E-03 5.34E-03
2500 240.35 0.02 0.01 0.01 9.54E-03 8.35E-03 7.42E-03 6.68E-03
3000 288.42 0.02 0.02 0.01 0.01 0.01 8.90E-03 8.01E-03
3500 336.49 0.02 0.02 0.02 0.01 0.01 0.01 9.35E-03
4000 384.56 0.03 0.02 0.02 0.02 0.01 0.01 0.01
4500 432.63 0.03 0.02 0.02 0.02 0.02 0.01 0.01
5000 480.70 0.03 0.03 0.02 0.02 0.02 0.01 0.01
5500 528.77 0.04 0.03 0.02 0.02 0.02 0.02 0.01
6000 576.84 0.04 0.03 0.03 0.02 0.02 0.02 0.02
6500 624.91 0.04 0.03 0.03 0.02 0.02 0.02 0.02
7000 672.98 0.05 0.04 0.03 0.03 0.02 0.02 0.02
7500 721.05 0.05 0.04 0.03 0.03 0.03 0.02 0.02
8000 769.12 0.05 0.04 0.04 0.03 0.03 0.02 0.02
8500 817.19 0.06 0.05 0.04 0.03 0.03 0.03 0.02
9000 865.26 0.06 0.05 0.04 0.03 0.03 0.03 0.02
9500 913.33 0.06 0.05 0.04 0.04 0.03 0.03 0.03
10000 961.40 0.07 0.05 0.04 0.04 0.03 0.03 0.03
15000 1442.10 0.10 0.08 0.07 0.06 0.05 0.04 0.04
20000 1922.80 0.13 0.11 0.09 0.08 0.07 0.06 0.05
25000 2403.50 0.17 0.13 0.11 0.10 0.08 0.07 0.07
30000 2884.20 0.20 0.16 0.13 0.11 0.10 0.09 0.08
35000 3364.90 0.23 0.19 0.16 0.13 0.12 0.10 0.09
40000 3845.60 0.27 0.21 0.18 0.15 0.13 0.12 0.11
45000 4326.30 0.30 0.24 0.20 0.17 0.15 0.13 0.12
50000 4807.00 0.33 0.27 0.22 0.19 0.17 0.15 0.13

* Storage/settling volume calculated using 25-year/5-minute storm event rainfall amounts over a 15-minute retention period for selected Ontario centres obtained from Atmospheric Environment Service, Environment Canada "Rainfall Intensity-Duration Frequency (IDF) Data."
Runoff coefficient of 95 percent has been used, meaning that 95 per cent of the rainfall entering the runoff collection area can be expected to enter the VFS system.

Back to Chapter 6 - Table of Contents



 


For more information:
Toll Free: 1-877-424-1300
Local: (519) 826-4047
E-mail: ag.info.omafra@ontario.ca
Author: Robert P. Stone, P. Eng., Engineer, Soil/OMAFRA
Creation Date: 04 July 2005
Last Reviewed: 20 June 2006